+86-592-5803997
video

HFC 227ea Clean Agent For Fire Suppressing

UL, REACH,ISO 9001, and CCC certified.
Zero ozone depletion potential.
Low global warming potential.
Short atmospheric lifetime.
Safe for occupied spaces.
Best warranty in the fire protection industry.
Extensive line of fire protection accessories.
Simplified installation.
Requires minimal container storage space.

Description

Xiamen Juda Chemical & Equipment Co., Ltd. is one of the leading manufacturers and suppliers of hfc 227ea clean agent for fire suppressing in China. If you are looking for hfc 227ea clean agent for fire suppressing, please be free to buy our quality products at competitive price from our factory. Contact us for quotation.

 

What Is HFC 227ea?

HFC 227ea, commonly known in the fire protection industry as FM200, is a well-established HFC clean agent widely used for fire suppressing inside enclosed high-value premises. Many fire protection engineers and facility buyers refer to this substance as HFC 227ea gas during system specification, tender evaluation and agent procurement work. As a clean agent, it was developed as a practical replacement for Halon, which carries ozone-depleting properties and faces global bans. Unlike water sprinklers, dry powder or foam fire suppression solutions, HFC 227ea is designed specifically to minimise secondary damage to sensitive electrical and electronic assets. When released, it vaporises fully without leaving solid particles, sticky films or corrosive deposits on equipment surfaces.

Applications:
 Telecommunications systems

 Computer rooms

 Laboratories

 Electrical cabinets and substations

 Control rooms

 Server rooms (data centers), etc.

Fire Suppressing agent HFC 227EA
Core Benefits of Using HFC 227ea

 

Electrically non-conductive for live electrical hazards

This clean agent will not conduct electricity during discharge. When deployed on energised servers, control panels, switchgear and UPS units, HFC 227ea gas avoids short circuits and further equipment breakdown. It is ideal for Class B flammable liquid fires and Class C energised electrical fires, the two most common hazards in mission-critical industrial and IT spaces.

 

Residue-free discharge to reduce downtime and cleanup work

After fire suppressing events, HFC 227ea gas disperses naturally through ventilation systems. There is no powder or oily residue left on circuit boards, sensors or precision machinery. Facility teams only need simple visual inspections instead of lengthy cleaning, which cuts recovery time and lowers business interruption losses.

 

Safe for occupied rooms within approved design concentration

Under NFPA 2001 and ISO 14520 standards, HFC 227ea clean agent can be installed in spaces where staff occasionally enter. Professional fire system designs include pre-alarm notifications and timed delays, giving operators enough time to evacuate before agent release. This makes it suitable for control rooms, telecom hubs and small server rooms with regular maintenance access.

 

Compact storage and mature system hardware

Compared with inert gas clean agent alternatives, HFC 227ea requires fewer and smaller storage cylinders to achieve the required suppressing concentration. Cylinder banks can be arranged in dedicated storage closets or external cabinet units, preserving usable floor area inside protected rooms. Global fire contractors are familiar with the calculation, piping, nozzle layout and commissioning workflow for HFC 227ea gas, which reduces project risks.

 

Key Engineering Requirements for HFC 227ea Fire Suppressing Systems

 

A reliable fire suppressing result depends heavily on system design rather than only sourcing HFC 227ea. Project planners should focus on these practical points.

 

Enclosure integrity testing is mandatory

Leaks around cable penetrations, loose ceiling tiles, poorly sealed doors and uncontrolled ventilation openings dilute HFC 227ea gas rapidly. The protected enclosure must hold the target agent concentration long enough to fully suppress flames. Room integrity tests need to be completed during commissioning and repeated during routine maintenance cycles.

 

Interlock with ventilation and HVAC equipment

When fire alarms activate, air handling fans, exhaust blowers and fire dampers must shut down automatically. Continuous air exchange will draw HFC 227ea out of the protected zone and weaken fire suppressing performance. All linkage functions should be fully tested during site acceptance.

 

Dual cross-zone fire detection setup

For high-value facilities, cross-zone smoke or heat detection logic is recommended. Two independent detectors need to confirm fire risk before triggering agent release. This setup greatly lowers the chance of accidental discharge caused by dust, construction disturbance or single-sensor faults.

 

Precise agent mass calculation

Engineers need to calculate the total protected volume, including raised floor plenums and ceiling voids. Ambient temperature, altitude and hazard classification all affect the required quantity of HFC 227ea. Rough estimates will lead to insufficient concentration and fire suppressing failure.

 

Physical & Chemical Properties

Attributes

Values

Chemical name

HFC-227ea, Heptafluoropropane, 1,1,1,2,3,3,3-Heptafluoropropane

Chemical formula CF3CHFCF3
Molecular formula C3HF7
CAS No. 431-89-0
ODP 0
GWP100 yr 3220
Atmospheric lifetime(years) 34
Molecular weight 170.03

Boiling point (℃)

-16.4

Freezing point (℃)

-131

Critical temperature (℃)

101.7

Critical pressure (kPa)

2925

Vapor pressure (kPa, @25℃)

454

Liquid density (g/ml, @25℃)

1.39

 

Request Technical Datasheet

 

HFC 227ea (FM-200) Packaging 

 

The most common packaging of HFC-227ea are:

hfc 227ea agent

13.6 kg disposable cylinder

hfc 227ea full form

1000 Ton Tank

 
Sourcing Certified HFC 227ea Gas for Fire Suppressing Projects

HFC 227EA SUPPLIER XIAMEN JUDA CHEMICAL EQUIPMENT COLTD

We supply bulk HFC 227ea for fire protection OEMs, fire engineering integrators and maintenance contractors around the world. Each batch of HFC 227ea is delivered with complete batch quality certificates, MSDS and supporting compliance documentation that meets international fire safety standards. Whether you are designing a brand-new fire suppressing system or ordering refills for existing installed FM200 hardware, our team provides technical datasheets, compliance guidance and stable bulk supply. Reach out to discuss your project parameters and request a quotation.

 

Get Free Quote Now

Send your request, we reply within 24 hours.

Hot Tags: hfc 227ea clean agent for fire suppressing, suppliers, manufacturers, factory, quotation, price, buy, Abc Chemicals Powder Of Fire Extinguishing Agent, Hfc 236fa, Hfc227ea Gas, Halon 1301 Replacement, Hfc 227ea, Halon Fire Extinguishers

Contact Supplier